How To Use Regular Consumables On A T2 Torch

December 2, 2021

You asked, so we’ve delivered. You’ve now got the choice to use a regular torch head and its parts, or you can stick with the T2 parts. Simply replace the head of your T2 torch with a 26 or 17 size head and have the option to use standard consumables or T2 consumables.

Changing the Torch Head

The best part about our replaceable torch heads is that it’s super easy to swap between the T2 and a standard head. Here’s how:

  1. Unscrew the 6 small screws on the T2 torch. With the screws removed, the outer plastic on the handle should be easy to pull off.
  2. Using a Stanley knife, cut the shrink sleeve off, revealing the nut that holds the torch head in place.
  3. Grab two 12mm spanners, and twisting in opposite directions, loosen the torch head.
  4. Remove the T2 torch head and swap it for a standard torch head.
  5. Tighten the new torch head using the 12mm spanners.
  6. Reassemble the torch handle, returning all the screws to their places.

And you’re done! Now you’ve got a torch head (size 17 or 26) that you can attach your standard consumables to. The torch consumables are assembled on the torch the same way as they normally would be.

Not only is swapping parts a breeze, but the replaceable heads are flexi-heads as well. So, they’re just as versatile as our T2 head.

If you ever want to swap back to our long-lasting, high-performance Arc Torchology consumables, just repeat the process. You can switch between the T2 head and a standard head in a matter of minutes.

Check out the T2 TIG Torch Head Replacements here

← See all articles